Just a Draft - will modify the content of this post
———————–
s400bk: Sun Solaris 9 server
StorEdge L500: Tape Library
NetApp Filer FAS940
s100bk.root# ./install
VERITAS Installation Script
Copyright 1993 - 2003 VERITAS Software Corporation, All Rights Reserved.
Installation Options
1 NetBackup Add-On Product Software
2 NetBackup Database Agent Software
q To quit from this script
Choose an option [default: q]: 1
**********
NetBackup Add-On Product Installation
Choose the Add-On Products you wish to install
one at a time or select Install All Add-On Products.
1) NetBackup Advanced Client
2) NetBackup Advanced Reporter
3) NetBackup for NDMP
4) NetBackup Vault
5) Install All Add-On Products
q) Done Selecting Products
x) Exit from this Script
Select the Advanced Client option if upgrading any of the
following products: Core Frozen Image Services, Extended
Frozen Image Services, FlashBackup or Offhost and SAN Data
Movement Services. The packages have been combined.
Choose an option:3
Choose an option: q
You have chosen to install these Add-On Products:
NetBackup for NDMP
Is this list correct? [y,n] (y)
**********
Enter the license key for NetBackup for NDMP or q to skip this product:XXX-XXX-.....-XXX
Installing NetBackup for NDMP
Processing package instance <VRTSnbdmp> from </cdrom/nb50_options_1106/vADD>
VERITAS NetBackup for NDMP
(sparc) 5.0,REV=2003.10.31.16.36
Copyright 1993 - 2003 VERITAS Software Corporation, All Rights Reserved.
NetBackup is currently installed in /netbackup/netbackup.
There is an existing link from /usr/openv to /netbackup.
WARNING: There is no openv directory to your NetBackup
install location, /netbackup.
This install will place binaries in //openv.
Do you want to continue this install? (y) [y,n,?,q]y
NetBackup for NDMP will be installed in //openv/lib.
NetBackup for NDMP for Solaris platforms will be loaded.
Cannot install when Media Manager daemons are running.
Do you want to kill Media Manager's daemons? (y) [y,n,?,q] y
Using </> as the package base directory.
## Processing package information.
## Processing system information.
## Verifying package dependencies.
## Verifying disk space requirements.
## Checking for conflicts with packages already installed.
Installing VERITAS NetBackup for NDMP as <VRTSnbdmp>
## Executing preinstall script.
## Installing part 1 of 1.
/openv/lib/libndmp_bpfsmap.so
/openv/lib/libndmpclient.so
/openv/volmgr/bin/ndmpmoveragent
/openv/volmgr/bin/ndmpmoveragent.start
/openv/volmgr/bin/ndmpmoveragent.stop
/openv/volmgr/bin/ndmpsocketmover
/openv/volmgr/bin/set_ndmp_attr
[ verifying class <NBnclass> ]
## Executing postinstall script.
Restarting ltid with optional parameters = ""
Installation of <VRTSnbdmp> was successful.
NetBackup for NDMP installation completed.
**********
Execution of ./install is complete.
File /tmp/install_options_trace.4858 contains a trace of this install.
VERITAS Installation Script
Copyright 1993 - 2003 VERITAS Software Corporation, All Rights Reserved.
Installation Options
1 NetBackup Add-On Product Software
2 NetBackup Database Agent Software
q To quit from this script
Choose an option [default: q]: q
------------------
Choose an option: 4
Choose an option: q
You have chosen to install these Add-On Products:
NetBackup Vault
Is this list correct? [y,n] (y)
s100bk.root# /usr/openv/volmgr/bin/set_ndmp_attr -auth f400cbe4 root
Password for host "f400cbe4" user "root":
Re-enter Password for host "f400cbe4" user "root":
Inserted host "f400cbe4"
s400cns12.root#
s400cns12.root# set_ndmp_attr -list
Record Type: Authentication
NDMP Server: f400cbe4
Username : root
Password : <registered>
s400cns12.root#
s400cns12.root# set_ndmp_attr -verify f400cbe4
Connecting to host "f400cbe4" as user "root"...
Waiting for connect notification message...
Opening session--attempting with NDMP protocol version 4...
Opening session--successful with NDMP protocol version 4
host supports MD5 authentication
Getting MD5 challenge from host...
Logging in using MD5 method...
ndmp_connect_client_auth failed
set_ndmp_attr: host "f400cbe4" failed
NDMP failed to verify host
s400cns12.root#
s400cns12.root# /usr/openv/volmgr/bin/set_ndmp_attr -auth f400cbe4 root
Password for host "f400cbe4" user "root":
Re-enter Password for host "f400cbe4" user "root":
Updated host "f400cbe4"
s400cns12.root# /usr/openv/volmgr/bin/set_ndmp_attr -verify f400cbe4
Connecting to host "f400cbe4" as user "root"...
Waiting for connect notification message...
Opening session--attempting with NDMP protocol version 4...
Opening session--successful with NDMP protocol version 4
host supports MD5 authentication
Getting MD5 challenge from host...
Logging in using MD5 method...
Host info is:
host name "F400CBE4"
os type "NetApp"
os version "NetApp Release 7.0.4"
host id "0050400873"
Login was successful
Host supports LOCAL backup/restore
Host supports 3-way backup/restore
s400cns12.root#
F400CBE4> sysconfig -A
NetApp Release 7.0.4: Sun Feb 5 00:52:53 PST 2006
System ID: 0050400873 (F400CBE4)
System Serial Number: 1037424 (F400CBE4)
System Rev: G1
Backplane Part Number: 104-00013
Backplane Rev: G1
Backplane Serial Number: 1037424
slot 0: System Board
Processors: 1
Memory Size: 3072 MB
slot 0: 10/100 Ethernet Controller IV
e0 MAC Address: 00:a0:98:01:1e:89 (auto-unknown-cfg_down)
slot 0: NetApp ATA/IDE Adapter 0a (0x000001f0)
0a.0 30MB
slot 1: Remote Management Controller
slot 4: Dual 10/100/1000 Ethernet Controller VI
e4a MAC Address: 00:04:23:b7:0e:be (auto-unknown-cfg_down)
e4b MAC Address: 00:04:23:b7:0e:bf (auto-unknown-cfg_down)
slot 5: FC Host Adapter 5a
slot 5: FC Host Adapter 5b
14 Disks: 5923.5GB
1 shelf with AT-FCX
slot 6: Dual Gigabit Ethernet Controller VI
e6a MAC Address: 00:04:23:cc:15:60 (auto-1000sx-fd-up)
e6b MAC Address: 00:04:23:cc:15:61 (auto-unknown-cfg_down)
slot 7: NetApp ATA/IDE Adapter 7 (0x0000afe0)
slot 7: NVRAM
Memory Size: 256 MB
slot 8: FC Host Adapter 8a
14 Disks: 5923.5GB
1 shelf with AT-FCX
slot 8: FC Host Adapter 8b
slot 9: Dual 10/100/1000 Ethernet Controller VI
e9a MAC Address: 00:04:23:b7:0f:e4 (auto-unknown-cfg_down)
e9b MAC Address: 00:04:23:b7:0f:e5 (auto-unknown-cfg_down)
slot 10: SCSI Host Adapter 10a
slot 10: SCSI Host Adapter 10b
1 Tape: Ultrium 3-SCSI
slot 11: Dual 10/100/1000 Ethernet Controller V
e11a MAC Address: 00:07:e9:3e:fd:12 (auto-1000t-fd-up)
e11b MAC Address: 00:07:e9:3e:fd:13 (auto-unknown-cfg_down)
sysconfig: There are no configuration errors.
Device HA SHELF BAY CHAN Disk Vital Product Information
---------- --------------- ----- ------------------------------
5b.16 5b 1 0 FC:A ZAH1HJ7F
8a.17 8a 1 1 FC:B ZAH1H83F
8a.18 8a 1 2 FC:B ZAH1HZ9F
5b.19 5b 1 3 FC:A ZAGZ0D0F
8a.20 8a 1 4 FC:B ZAGZ0BTF
8a.21 8a 1 5 FC:B ZAH1GPDF
8a.22 8a 1 6 FC:B ZAH3DEXF
8a.23 8a 1 7 FC:B ZAGY7NEF
5b.24 5b 1 8 FC:A ZAGZX1BF
5b.25 5b 1 9 FC:A ZAH1GN8F
8a.26 8a 1 10 FC:B ZAH1HJ6F
5b.27 5b 1 11 FC:A ZAH1J8SF
8a.28 8a 1 12 FC:B ZAH1HPNF
5b.29 5b 1 13 FC:A ZAGYD8EF
volume aggr0 (1 RAID group):
group 0: 13 disks
Aggregate aggr0 (online, raid_dp) (block checksums)
Plex /aggr0/plex0 (online, normal, active)
RAID group /aggr0/plex0/rg0 (normal)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 5b.16 5b 1 0 FC:A - ATA 7200 423111/866531584 423889/868126304
parity 8a.17 8a 1 1 FC:B - ATA 7200 423111/866531584 423889/868126304
data 8a.18 8a 1 2 FC:B - ATA 7200 423111/866531584 423889/868126304
data 5b.19 5b 1 3 FC:A - ATA 7200 423111/866531584 423889/868126304
data 8a.20 8a 1 4 FC:B - ATA 7200 423111/866531584 423889/868126304
data 8a.21 8a 1 5 FC:B - ATA 7200 423111/866531584 423889/868126304
data 8a.22 8a 1 6 FC:B - ATA 7200 423111/866531584 423889/868126304
data 8a.23 8a 1 7 FC:B - ATA 7200 423111/866531584 423889/868126304
data 5b.24 5b 1 8 FC:A - ATA 7200 423111/866531584 423889/868126304
data 5b.25 5b 1 9 FC:A - ATA 7200 423111/866531584 423889/868126304
data 8a.26 8a 1 10 FC:B - ATA 7200 423111/866531584 423889/868126304
data 5b.27 5b 1 11 FC:A - ATA 7200 423111/866531584 423889/868126304
data 8a.28 8a 1 12 FC:B - ATA 7200 423111/866531584 423889/868126304
Spare disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
Spare disks for block or zoned checksum traditional volumes or aggregates
spare 5b.29 5b 1 13 FC:A - ATA 7200 423111/866531584 423889/868126304
No medium changers present on system.
Tape drive (10b.1) HP Ultrium 3-SCSI
rst0l - rewind device, format is: LTO-I rd only 200GB cmp
nrst0l - no rewind device, format is: LTO-I rd only 200GB cmp
urst0l - unload/reload device, format is: LTO-I rd only 200GB cmp
rst0m - rewind device, format is: LTO-II 400GB cmp
nrst0m - no rewind device, format is: LTO-II 400GB cmp
urst0m - unload/reload device, format is: LTO-II 400GB cmp
rst0h - rewind device, format is: LTO-III 400GB
nrst0h - no rewind device, format is: LTO-III 400GB
urst0h - unload/reload device, format is: LTO-III 400GB
rst0a - rewind device, format is: LTO-III 800GB cmp
nrst0a - no rewind device, format is: LTO-III 800GB cmp
urst0a - unload/reload device, format is: LTO-III 800GB cmp
F400CBE4> sysconfig -v
NetApp Release 7.0.4: Sun Feb 5 00:52:53 PST 2006
System ID: 0050400873 (F400CBE4)
System Serial Number: 1037424 (F400CBE4)
System Rev: G1
Backplane Part Number: 104-00013
Backplane Rev: G1
Backplane Serial Number: 1037424
slot 0: System Board 1791 MHz (NetApp System Board VIII A1)
Model Name: FAS940
Part Number: 110-00002
Revision: A1
Serial Number: G7GFR2AD360039
Firmware release: 4.3.1_i2
BMC info: IPMI v1.5, BMC rev 0.20, SDR Version 00.20
Processors: 1
Memory Size: 3072 MB
slot 0: 10/100 Ethernet Controller IV
e0 MAC Address: 00:a0:98:01:1e:89 (auto-unknown-cfg_down)
Device Type: Rev 2
slot 0: NetApp ATA/IDE Adapter 0a (0x000001f0)
0a.0 SanDisk SDCFB-32 1.23 30MB 512B/sect (004202F2303E3718)
slot 1: Remote Management Controller
Serial Number: DE433600998
Firmware Version: RMC_NA_1.2
POST Status: OK
Mgmt MAC Address: 00:30:d3:07:ff:2e (auto)
LAN dhcp y ip 192.168.11.144 netmask 255.255.248.0 gw 192.168.11.254
slot 4: Dual 10/100/1000 Ethernet Controller VI
e4a MAC Address: 00:04:23:b7:0e:be (auto-unknown-cfg_down)
e4b MAC Address: 00:04:23:b7:0e:bf (auto-unknown-cfg_down)
Device Type: Rev 3
slot 5: FC Host Adapter 5a (Dual-channel, QLogic 2312 (2342) rev. 2, 64-bit, L-port, <OFFLINE (hard)>)
Firmware rev: 3.3.142
Host Loop Id: 0 FC Node Name: 2:000:00e08b:13c16b
Cacheline size: 16 FC Packet size: 2048
SRAM parity: Yes External GBIC: No
Link Data Rate: 1 Gbit
slot 5: FC Host Adapter 5b (Dual-channel, QLogic 2312 (2342) rev. 2, 64-bit, L-port, <UP>)
Firmware rev: 3.3.142
Host Loop Id: 7 FC Node Name: 2:001:00e08b:33c16b
Cacheline size: 16 FC Packet size: 2048
SRAM parity: Yes External GBIC: No
Link Data Rate: 2 Gbit
16: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
17: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
18: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
19: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
20: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
21: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
22: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
23: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
24: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
25: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
26: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
27: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
28: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
29: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
Shelf 1: AT-FCX Firmware rev. AT-FCX A: 32 AT-FCX B: 32
slot 6: Dual Gigabit Ethernet Controller VI
e6a MAC Address: 00:04:23:cc:15:60 (auto-1000sx-fd-up)
e6b MAC Address: 00:04:23:cc:15:61 (auto-unknown-cfg_down)
Device Type: Rev 3
slot 7: NetApp ATA/IDE Adapter 7 (0x0000afe0)
slot 7: NVRAM (NetApp NVRAM IV)
Revision: C0
Serial Number: 69225
Memory Size: 256 MB
Battery Status: OK
Running Microcode Revision: 0115
slot 8: FC Host Adapter 8a (Dual-channel, QLogic 2312 (2342) rev. 2, 64-bit, L-port, <UP>)
Firmware rev: 3.3.142
Host Loop Id: 7 FC Node Name: 2:000:00e08b:1cafb9
Cacheline size: 16 FC Packet size: 2048
SRAM parity: Yes External GBIC: No
Link Data Rate: 2 Gbit
16: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
17: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
18: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
19: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
20: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
21: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
22: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
23: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
24: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
25: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
26: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
27: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
28: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
29: NETAPP X267_HKURO500SSX AB0A 423.1GB (976642092 512B/sect)
Shelf 1: AT-FCX Firmware rev. AT-FCX A: 32 AT-FCX B: 32
slot 8: FC Host Adapter 8b (Dual-channel, QLogic 2312 (2342) rev. 2, 64-bit, L-port, <OFFLINE (hard)>)
Firmware rev: 3.3.142
Host Loop Id: 0 FC Node Name: 2:001:00e08b:3cafb9
Cacheline size: 16 FC Packet size: 2048
SRAM parity: Yes External GBIC: No
Link Data Rate: 1 Gbit
slot 9: Dual 10/100/1000 Ethernet Controller VI
e9a MAC Address: 00:04:23:b7:0f:e4 (auto-unknown-cfg_down)
e9b MAC Address: 00:04:23:b7:0f:e5 (auto-unknown-cfg_down)
Device Type: Rev 3
slot 10: SCSI Host Adapter 10a (Adaptec AIC7902, <ONLINE>)
HW Version 0.0
Ultra320 SCSI, Low Voltage Differential
slot 10: SCSI Host Adapter 10b (Adaptec AIC7902, <ONLINE>)
HW Version 0.0
Ultra320 SCSI, Low Voltage Differential
1: Tape: HP Ultrium 3-SCSI G24S
slot 11: Dual 10/100/1000 Ethernet Controller V
e11a MAC Address: 00:07:e9:3e:fd:12 (auto-1000t-fd-up)
e11b MAC Address: 00:07:e9:3e:fd:13 (auto-unknown-cfg_down)
Device Type: Rev 1
F400CBE4>
F400CBE4>
F400CBE4> ndmpd version
ndmpd highest version set to: 4
F400CBE4>
F400CBE4> storage show tape supported
Supported Tapes
---------------
Exabyte 8500C 8mm
Exabyte 8505 8mm
Exabyte 8900 8mm
Exabyte 8500 8mm
Exabyte Mammoth-2 8mm
Digital DLT2000
Quantum DLT2000
Sun DLT2000
Digital DLT4000
Quantum DLT4000
Sun DLT4000
Digital DLT7000
Quantum DLT7000
Sun DLT7000
Digital DLT8000
Quantum DLT8000
Sun DLT8000
Quantum SDLT220
Quantum SDLT320
Digital DLT2700
Quantum DLT2700
Sun DLT2700
Digital DLT4500
Quantum DLT4500
Sun DLT4500
Digital DLT4700
Quantum DLT4700
Sun DLT4700
Hewlett-Packard C1533A
Hewlett-Packard C1553A
Hewlett-Packard Ultrium 1
Sony SDX-300C
Sony SDX-500C
Sony SDX-700C
Sony GY-8240
Sony GY-2120
StorageTek 9840
StorageTek T9840B
StorageTek T9940A
StorageTek T9940B
Seagate ULTRIUM06242
IBM ULT3580-TD1
IBM ULTRIUM-TD1
IBM 03590B
IBM 03590E
IBM 03590H
HP Ultrium 2-SCSI - Dynamically Qualified
Hewlett-Packard LTO-3 - Dynamically Qualified
IBM 3592 - Dynamically Qualified
IBM ULT3580-TD2 - Dynamically Qualified
IBM ULTRIUM-TD2 - Dynamically Qualified
IBM LTO 3 ULT3580 - Dynamically Qualified
IBM LTO 3 ULTRIUM - Dynamically Qualified
Quantum SuperDLT 600 - Dynamically Qualified
Sony AIT-3 (SDX-700V) - Dynamically Qualified
Sony AIT-4 SDX-900V - Dynamically Qualified
Sony SAIT-1 (SDZ-100) - Dynamically Qualified
Sony SAIT-1 (SDZ-130) - Dynamically Qualified
StorageTek T9840C - Dynamically Qualified
F400CBE4>
F400CBE4> storage stats tape nrst0a
Bytes Read: 0
Bytes Written: 0
Command Num issued Max (ms) Min (ms) Avg (ms)
------- ---------- -------- -------- --------
WRITE - Total 0 0 0 0
READ - Total 0 0 0 0
WEOF 0 0 0 0
FSF 0 0 0 0
BSF 0 0 0 0
FSR 0 0 0 0
BSR 0 0 0 0
REWIND 0 0 0 0
ERASE 0 0 0 0
EOM 0 0 0 0
F400CBE4>
Recent Comments